IED Clearance Good Practice Guide

Search lane progression and boundary markers

Tripwire feeler

Image 2. Crow’s foot method – tripwire feeling

The following series of six images illustrates the basics of an open area tripwire feeling procedure. They show the systematic use of a tripwire feeler, starting from ground level, to waist height, then on to head height from the standing position.

ׁ HINT. The degree to which tripwire feeling is conducted should be driven by the operational threat assessment. This should be documented in the clearance plan.

Tripwire feeler

Image 3. Low level starting at the side (this would be conducted at each side of the lane)

Search core skills and procedures

177