IED Clearance Good Practice Guide

Below is an example plan:

ACTION CONDUCTED

MOST LIKELY OUTCOME

WORST CASE OUTCOME

PHASE

EQUIPMENT

Neutralisation of power source

ROV with loaded barrel disruptor

Remote 1

Disruption

Device detonates

Component separation

No disruption – repeat Remote 1

Remote 2

Confirm disruption

None

Torch disruptor

Confirm disruption

Detonator safety equipment (insulation tape, scalpel, snips, detonator recovery container)

Disruption has failed – place manual disruptor

Conduct detonator safety

Disruption successful

Manual 1

Set H&L to semi- remotely remove main charge

H&L (line, change of direction, strop, karabiner)

Continues as required…

Continues as required…

Continues as required…

Continues as required…

Continues as required…

ׁ HINT. Write the plan on a task site whiteboard as this will make it easier to make amendments or updates.

As the task progresses more information may become available through further questioning, remote observation or first-hand experience. There should be continual evaluation conducted throughout the task to allow this new information to be incorporated into the plan.

ׁ WARNING. Endeavor to return to using remote means wherever possible.

IEDD task conduct