IED Clearance Good Practice Guide

OPPORTUNITY

Physical link command wire

Image 75. Physical link command wire shown as a red line

The state armed group had become confident in the use of their jammers and if a route had been trafficked by civilians then they would believe it to be safe. They did not conduct checks before, or even after they stopped their vehicles, or pay particular attention to VPs such as main track junctions.

Linked main charges

Linked main charges

Vulnerable point

Vulnerable point

Linked main charges

Image 76. Linked main charges in the assessed location where vehicles would stop (or vulnerable point)

THREAT SUMMARY

A command-wire IED is probably located at the vulnerable point formed by the main track junction. This may have up to three main charges, probably AXO / UXO HE or HME packed into expended EO carrier munitions. The possibility of VOIEDs is assessed as very low.

Technical IED capabilities

70

Powered by